Evaluation on the operation of Refrigerated Container Van IRCU200215-2 as per submitted data records

May 01, 2016      - Operation is normal

May 02, 2016      - Operation is normal until
      Unit Power shutdown at 16:24H, no data recorded after shutdown

May 03, 2016      - Resume operation at 00:20H, unit was not in operation for
almost 8 hours from the time of shutdown on 5-02-16/16:24H.
From the recorded data shown 24hours, Supply air and Return air was in
semi-abnormal mode, with this temperature, frozen meat were begin to
melt.
01:00H to 20:00H  - (Semi-abnormal operation) Technician on duty who conducts every 3 hour inspection should notice this activity and did some inspection inside the unit.
20:44H – Technician change the settings of DEFROST interval to 3 hours
21:21H – Initiated manual defrost

May 04, 2016      - The unit was in semi abnormal state
      Several manual defrost was initiated
02:06 Initiated manual defrost
      04:10 Initiated manual defrost
08:45 Initiated manual defrost
10:34 Power Down
11:36 Power On
11:39 Manual Pre-Trip Initiated By Keypad - Test run
11:44 Initiated manual defrost
13:00H – 24:00H   - Unit is in Recovery Mode


May 05, 2016      - Unit is in recovery mode (semi normal operation)

May 06, 2016      - Unit is in recovery mode (semi normal operation)

May 07, 2016      - Unit is in recovery mode (normal operation)

May 08, 2016      - Unit is in recovery mode (normal operation)

May 09, 2016      - Unit is in recovery mode (normal operation)

May 10, 2016      - Unit is in recovery mode (normal operation)

May 11, 2016      - Unit is in recovery mode (normal operation)



*Note: This is my only observation for reference use.





 



May 01, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -24.72  -14.00
02:00    -25.23  -13.65
03:00    -26.01  -13.12
04:00    -26.80  -12.40
05:00    -27.43  -11.66
06:00    -24.62   -9.58
07:00    -15.21   -7.29
08:00    -22.62  -14.13
09:00    -22.43  -14.13
10:00    -23.59  -15.23
11:00    -23.88  -15.47             OPERATION IS NORMAL
12:00    -24.16  -15.63
13:00    -24.39  -15.71
14:00    -24.64  -15.71
15:00    -24.88  -15.69
16:00    -25.20  -15.73
17:00    -25.33  -15.55
18:00    -25.38  -15.33
19:00    -25.35  -15.35
20:00    -25.55  -14.79
21:00    -25.96  -14.37
22:00    -26.55  -13.62
23:00    -26.87  -12.63
24:00    -26.32  -11.55

May 01, 2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
01:00 Controller Alarms: 53 - Battery Pack Failure
02:00 Controller Alarms: 53 - Battery Pack Failure
03:00 Controller Alarms: 53 - Battery Pack Failure
04:00 Controller Alarms: 53 - Battery Pack Failure
05:00 Controller Alarms: 53 - Battery Pack Failure
05:37 Defrost Initiated By Timer
05:37 Operating Mode Changed to Defrost
06:00 Controller Alarms: 53 - Battery Pack Failure
06:12 Defrost Terminated Due to Normal Operation
06:21 No Active DataCorder Alarms
06:21 Operating Mode Changed to Cool Reduced
06:23 Operating Mode Changed to Cool Max
07:00 Controller Alarms: 53 - Battery Pack Failure
08:00 Controller Alarms: 53 - Battery Pack Failure
08:01 Power Down (Battery Not Present)
08:09 Power On (Battery Not Present)
08:10 Operating Mode Changed to Cool Reduced
08:12 Operating Mode Changed to Cool Max
09:00 Controller Alarms: 53 - Battery Pack Failure
10:00 Controller Alarms: 53 - Battery Pack Failure
11:00 Controller Alarms: 53 - Battery Pack Failure
12:00 Controller Alarms: 53 - Battery Pack Failure
13:00 Controller Alarms: 53 - Battery Pack Failure
14:00 Controller Alarms: 53 - Battery Pack Failure
15:00 Controller Alarms: 53 - Battery Pack Failure
16:00 Controller Alarms: 53 - Battery Pack Failure
17:00 Controller Alarms: 53 - Battery Pack Failure
18:00 Controller Alarms: 53 - Battery Pack Failure
19:00 Controller Alarms: 53 - Battery Pack Failure
20:00 Controller Alarms: 53 - Battery Pack Failure
21:00 Controller Alarms: 53 - Battery Pack Failure
22:00 Controller Alarms: 53 - Battery Pack Failure
23:00 Controller Alarms: 53 - Battery Pack Failure
23:50 Defrost Initiated Due to Delta Temp
23:50 Operating Mode Changed to Defrost
_______________________________________________________
 May 02, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -12.46   -4.80
02:00    -21.77  -13.36
03:00    -22.97  -14.73
04:00    -23.53  -15.28
05:00    -23.81  -15.47
06:00    -24.05  -15.58
07:00    -24.35  -15.62             OPERATION IS NORMAL
08:00    -24.64  -15.66
09:00    -24.98  -15.70
10:00    -25.31  -15.72
11:00    -25.57  -15.65
12:00    -25.92  -15.61
13:00    -26.23  -15.99
14:00    -26.62  -15.71
15:00    -27.11  -15.40
16:00    -23.31  -10.38

May 02,2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
00:00 Defrost Initiated - Active from Previous Day
00:29 Defrost Terminated Due to Normal Operation
00:37 Operating Mode Changed to Cool Reduced
00:39 Operating Mode Changed to Cool Max
01:00 Controller Alarms: 53 - Battery Pack Failure
02:00 Controller Alarms: 53 - Battery Pack Failure
03:00 Controller Alarms: 53 - Battery Pack Failure
04:00 Controller Alarms: 53 - Battery Pack Failure
05:00 Controller Alarms: 53 - Battery Pack Failure
06:00 Controller Alarms: 53 - Battery Pack Failure
07:00 Controller Alarms: 53 - Battery Pack Failure
08:00 Controller Alarms: 53 - Battery Pack Failure
09:00 Controller Alarms: 53 - Battery Pack Failure
10:00 Controller Alarms: 53 - Battery Pack Failure
11:00 Controller Alarms: 53 - Battery Pack Failure
12:00 Controller Alarms: 53 - Battery Pack Failure
13:00 Controller Alarms: 53 - Battery Pack Failure
14:00 Controller Alarms: 53 - Battery Pack Failure
15:00 Controller Alarms: 53 - Battery Pack Failure
15:30 Defrost Initiated Due to Delta Temp
15:30 Operating Mode Changed to Defrost
16:00 Controller Alarms: 53 - Battery Pack Failure
16:04 Defrost Terminated Due to Normal Operation
16:13 Operating Mode Changed to Cool Reduced
16:14 Operating Mode Changed to Cool Max
16:24 Power Down (Battery Not Present)
_______________________________________________________

May 03, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -11.43   -3.91       Semi-abnormal operation
02:00    -16.05   -7.36
03:00    -17.29   -4.66
04:00     -7.65    1.35
05:00    -15.55   -6.48
06:00    -19.10   -7.67       Technician should begin
07:00    -10.27   -0.37       to check the unit
08:00    -15.90   -6.72
09:00    -19.17   -7.99
10:00    -11.19   -1.37
11:00    -16.24   -6.66
12:00    -19.35   -8.26
13:00    -14.28   -2.33
14:00    -14.52   -6.17
15:00    -19.31   -8.11
16:00    -17.38   -5.40
17:00    -12.26   -3.73
18:00    -18.53   -7.61
19:00    -20.48   -7.50

Time  Event Data
00:20 Power On (Battery Not Present)
00:20 Controller Alarms: 53 - Battery Pack Failure
00:22 Operating Mode Changed to Cool Reduced
00:45 Operating Mode Changed to Cool Max
01:00 Controller Alarms: 53 - Battery Pack Failure
02:00 Controller Alarms: 53 - Battery Pack Failure
03:00 Controller Alarms: 53 - Battery Pack Failure
03:10 Defrost Initiated Due to Delta Temp
03:46 Defrost Terminated Due to Normal Operation
03:55 Operating Mode Changed to Modulated Cool
03:55 Operating Mode Changed to Cool Reduced
04:00 Controller Alarms: 53 - Battery Pack Failure
04:15 Operating Mode Changed to Cool Max
05:00 Controller Alarms: 53 - Battery Pack Failure
06:00 Controller Alarms: 53 - Battery Pack Failure
06:12 Defrost Initiated Due to Delta Temp
06:48 Defrost Terminated Due to Normal Operation
06:56 Operating Mode Changed to High Speed Evaps
06:56 Operating Mode Changed to Cool Reduced
07:00 Controller Alarms: 53 - Battery Pack Failure
07:17 Operating Mode Changed to Cool Max
08:00 Controller Alarms: 53 - Battery Pack Failure
09:00 Controller Alarms: 53 - Battery Pack Failure
09:14 Defrost Initiated Due to Delta Temp
09:49 Defrost Terminated Due to Normal Operation
09:57 Operating Mode Changed to High Speed Evaps
09:58 Operating Mode Changed to Cool Reduced
10:00 Controller Alarms: 53 - Battery Pack Failure
10:17 Operating Mode Changed to Cool Max
11:00 Controller Alarms: 53 - Battery Pack Failure
12:00 Controller Alarms: 53 - Battery Pack Failure
12:22 Defrost Initiated Due to Delta Temp
12:22 Operating Mode Changed to Defrost
12:57 Defrost Terminated Due to Normal Operation
13:00 Controller Alarms: 53 - Battery Pack Failure
13:06 Operating Mode Changed to Cool Reduced
13:07 Operating Mode Changed to Cool Max
14:00 Controller Alarms: 53 - Battery Pack Failure
15:00 Controller Alarms: 53 - Battery Pack Failure
15:32 Defrost Initiated Due to Delta Temp
15:32 Operating Mode Changed to Defrost
16:00 Controller Alarms: 53 - Battery Pack Failure
16:06 Defrost Terminated Due to Normal Operation
16:15 Operating Mode Changed to Cool Reduced
16:16 Operating Mode Changed to Cool Max
17:00 Controller Alarms: 53 - Battery Pack Failure
18:00 Controller Alarms: 53 - Battery Pack Failure
18:57 Defrost Initiated Due to Delta Temp
18:57 Operating Mode Changed to Defrost
19:00 Controller Alarms: 53 - Battery Pack Failure
19:32 Defrost Terminated Due to Normal Operation
_______________________________________________________


May 03, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
20:00     -9.43   -0.63
22:00     -3.14    2.52
23:00    -15.70   -5.84
24:00    -18.05   -7.25

May 03, 2016
Time  Event Data
19:40 Operating Mode Changed to Cool Reduced
19:58 Operating Mode Changed to Cool Max
20:00 Controller Alarms: 53 - Battery Pack Failure
20:44 User Selectable Change: Defrost Interval changed to 3 hours By Keypad
20:45 Power Down (Battery Not Present)
21:19 Power On (Battery Not Present)
21:20 Controller Alarms: 53 - Battery Pack Failure
21:21 Defrost Initiated By Keypad                     - Manual Defrost
21:48 Defrost Terminated Due to Normal Operation
21:56 Operating Mode Changed to Modulated Cool
21:56 Operating Mode Changed to Cool Reduced
22:00 Controller Alarms: 53 - Battery Pack Failure
22:19 Operating Mode Changed to Cool Max
23:00 Controller Alarms: 53 - Battery Pack Failure
_______________________________________________________





May 04, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -19.65   -6.83
02:00     -9.00   -0.16       - Manual Defrost
03:00     -9.01   -0.49       Semi-abnormal operation
04:00    -17.01   -6.75
05:00    -10.21   -1.76       - Manual Defrost
06:00    -17.43   -6.94
07:00    -19.30   -8.36
08:00    -20.53   -8.61                  
09:00     -8.73   -1.00
10:00    -11.52   -2.34
12:00     -3.96   -2.73

May 04,2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
00:51 Defrost Initiated Due to Delta Temp
00:51 Operating Mode Changed to Defrost
01:00 Controller Alarms: 53 - Battery Pack Failure
01:28 Defrost Terminated Due to Normal Operation
01:37 Operating Mode Changed to Modulated Cool
01:37 Operating Mode Changed to Cool Reduced
02:00 Controller Alarms: 53 - Battery Pack Failure
02:06 Defrost Initiated By Keypad                     - Manual Defrost
02:35 Defrost Terminated Due to Normal Operation
02:44 Operating Mode Changed to Modulated Cool
02:44 Operating Mode Changed to Cool Reduced
03:00 Controller Alarms: 53 - Battery Pack Failure
03:06 Operating Mode Changed to Cool Max
04:00 Controller Alarms: 53 - Battery Pack Failure
04:10 Defrost Initiated By Keypad                     - Manual Defrost
04:42 Defrost Terminated Due to Normal Operation
04:50 Operating Mode Changed to Modulated Cool
04:50 Operating Mode Changed to Cool Reduced
05:00 Controller Alarms: 53 - Battery Pack Failure
05:12 Operating Mode Changed to Cool Max
06:00 Controller Alarms: 53 - Battery Pack Failure
07:00 Controller Alarms: 53 - Battery Pack Failure
07:51 Defrost Initiated By Timer
07:51 Operating Mode Changed to Defrost
08:00 Controller Alarms: 53 - Battery Pack Failure
08:28 Defrost Terminated Due to Normal Operation
08:39 Operating Mode Changed to Cool Max
08:45 Defrost Initiated By Keypad                     - Manual Defrost
08:45 Operating Mode Changed to Defrost
09:00 Controller Alarms: 53 - Battery Pack Failure
09:12 Defrost Terminated Due to Normal Operation
09:21 Operating Mode Changed to Cool Reduced
09:29 Operating Mode Changed to Cool Max
10:00 Controller Alarms: 53 - Battery Pack Failure
10:34 Power Down (Battery Not Present)
11:36 Power On (Battery Not Present)
11:36 Controller Alarms: 53 - Battery Pack Failure
11:37 Power Down (Battery Not Present)
11:37 Power On (Battery Not Present)
11:39 Manual Pre-Trip Initiated By Keypad
11:41 P3-0 Low Evap On Test: Passed- A: 1.50, B: 2.05, C: 1.50
      P3-1 Low Evap Off Test: Passed- A: 1.50, B: 2.03, C: 1.50
11:42 P4-0 High Evap On Test: Passed- A: 1.56, B: 2.77, C: 1.56, Ratio: 1.77
      P4-1 High Evap Off Test: Passed- A: 1.55, B: 2.77, C: 1.55
      P4-2 Remote Evap Fans On Test: Not Run
11:42 Pre-Trip Test Termination
      P1-0: Not Run P1-1: Not Run P1-2: Not Run
      P2-0: Not Run P2-1: Not Run
      P3-0: Passed P3-1: Passed
      P4-0: Passed P4-1: Passed P4-2: Not Run
      P5-0: Not Run P5-1: Not Run P5-2: Not Run P5-3: Not Run P5-4: Not Run
            P5-5: Not Run P5-6: Not Run P5-7: Not Run P5-8: Not Run
            P5-9: Not Run P5-10: Not Run P5-11: Not Run P5-12: Not Run
      P6-0: Not Run P6-1: Not Run P6-2: Not Run P6-3: Not Run P6-4: Not Run
            P6-5: Not Run P6-6: Not Run P6-7: Not Run P6-8: Not Run
            P6-9: Not Run P6-10: Not Run P6-11: Not Run
      P7-0: Not Run P7-1: Not Run
      P8-0: Not Run P8-1: Not Run P8-2: Not Run
      P9-0: Not Run
      P10-0: Not Run P10-1: Not Run P10-2: Not Run
11:43 Operating Mode Changed to Cool Reduced
11:44 Defrost Initiated By Keypad
11:44 Operating Mode Changed to Defrost
12:00 Controller Alarms: 53 - Battery Pack Failure
12:13 Defrost Terminated Due to Normal Operation
12:21 Operating Mode Changed to High Speed Evaps
_______________________________________________________

May 04, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
13:00    -10.93   -2.26
14:00    -19.17   -8.53
15:00    -21.17   -9.66
16:00    -16.51   -3.38
17:00    -14.77   -6.78
18:00    -18.81   -8.20
19:00    -10.55   -2.38
20:00    -17.79   -7.63
21:00    -19.17   -8.31
22:00    -17.80   -7.20
23:00    -11.88   -3.82
24:00    -17.86   -7.51

May 04, 2016
Time  Event Data
12:21 Operating Mode Changed to Cool Reduced
12:23 Operating Mode Changed to Cool Max
13:00 Controller Alarms: 53 - Battery Pack Failure
14:00 Controller Alarms: 53 - Battery Pack Failure
15:00 Controller Alarms: 53 - Battery Pack Failure
15:22 Defrost Initiated By Timer
15:22 Operating Mode Changed to Defrost
15:59 Defrost Terminated Due to Normal Operation
16:00 Controller Alarms: 53 - Battery Pack Failure
16:07 Operating Mode Changed to Cool Reduced
16:27 Operating Mode Changed to Cool Max
17:00 Controller Alarms: 53 - Battery Pack Failure
17:56 Defrost Initiated By Keypad
17:56 Operating Mode Changed to Defrost
18:00 Controller Alarms: 53 - Battery Pack Failure
18:27 Defrost Terminated Due to Normal Operation
18:36 Operating Mode Changed to Cool Reduced
18:56 Operating Mode Changed to Cool Max
19:00 Controller Alarms: 53 - Battery Pack Failure
20:00 Controller Alarms: 53 - Battery Pack Failure
21:00 Controller Alarms: 53 - Battery Pack Failure
21:37 Defrost Initiated By Timer
21:37 Operating Mode Changed to Defrost
22:00 Controller Alarms: 53 - Battery Pack Failure
22:11 Defrost Terminated Due to Normal Operation
22:20 Operating Mode Changed to Cool Reduced
22:38 Operating Mode Changed to Cool Max
23:00 Controller Alarms: 53 - Battery Pack Failure
23:53 Defrost Initiated By Keypad
23:53 Operating Mode Changed to Defrost
_______________________________________________________

May 05, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -10.54   -1.91
02:00    -18.60   -8.12
03:00    -20.30   -9.18
04:00    -18.75   -7.29
05:00    -13.17   -4.74
06:00    -19.32   -8.81
07:00    -20.47   -9.68
08:00    -11.53   -2.55
09:00    -18.97   -8.83
10:00    -20.10   -9.54
11:00    -19.88   -9.46
12:00    -12.08   -3.20
13:00    -19.53   -9.24
14:00    -20.54   -9.86
15:00    -18.19   -7.98
16:00    -13.75   -3.71
17:00    -19.60   -9.40
18:00    -10.81    0.57
19:00    -18.27   -8.69
20:00    -19.63   -9.30

May 05, 2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
00:00 Defrost Initiated - Active from Previous Day
00:24 Defrost Terminated Due to Normal Operation
00:33 Operating Mode Changed to Cool Reduced
00:53 Operating Mode Changed to Cool Max
01:00 Controller Alarms: 53 - Battery Pack Failure
02:00 Controller Alarms: 53 - Battery Pack Failure
03:00 Controller Alarms: 53 - Battery Pack Failure
03:35 Defrost Initiated By Timer
03:35 Operating Mode Changed to Defrost
04:00 Controller Alarms: 53 - Battery Pack Failure
04:10 Defrost Terminated Due to Normal Operation
04:18 Operating Mode Changed to Cool Reduced
04:36 Operating Mode Changed to Cool Max
05:00 Controller Alarms: 53 - Battery Pack Failure
06:00 Controller Alarms: 53 - Battery Pack Failure
07:00 Controller Alarms: 53 - Battery Pack Failure
07:00 Defrost Initiated By Keypad
07:35 Defrost Terminated Due to Normal Operation
07:43 Operating Mode Changed to High Speed Evaps
07:43 Operating Mode Changed to Cool Reduced
08:00 Controller Alarms: 53 - Battery Pack Failure
08:03 Operating Mode Changed to Cool Max
09:00 Controller Alarms: 53 - Battery Pack Failure
10:00 Controller Alarms: 53 - Battery Pack Failure
10:45 Defrost Initiated By Timer
10:45 Operating Mode Changed to Defrost
11:00 Controller Alarms: 53 - Battery Pack Failure
11:21 Defrost Terminated Due to Normal Operation
11:30 Operating Mode Changed to Cool Reduced
11:31 Operating Mode Changed to Cool Max
12:00 Controller Alarms: 53 - Battery Pack Failure
13:00 Controller Alarms: 53 - Battery Pack Failure
14:00 Controller Alarms: 53 - Battery Pack Failure
14:32 Defrost Initiated By Timer
14:32 Operating Mode Changed to Defrost
15:00 Controller Alarms: 53 - Battery Pack Failure
15:10 Defrost Terminated Due to Normal Operation
15:19 Operating Mode Changed to Cool Reduced
15:21 Operating Mode Changed to Cool Max
16:00 Controller Alarms: 53 - Battery Pack Failure
17:00 Controller Alarms: 53 - Battery Pack Failure
17:05 Defrost Initiated By Keypad
17:43 Defrost Terminated Due to Normal Operation
17:52 Operating Mode Changed to Modulated Cool
17:52 Operating Mode Changed to Cool Reduced
18:00 Controller Alarms: 53 - Battery Pack Failure
18:15 Operating Mode Changed to Cool Max
19:00 Controller Alarms: 53 - Battery Pack Failure
20:00 Controller Alarms: 53 - Battery Pack Failure
_______________________________________________________

May 05, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
21:00    -20.28  -10.09
22:00    -11.07   -2.03
23:00    -18.53   -8.92
24:00    -19.27   -9.31

May 05, 2016
Time  Event Data
20:54 Defrost Initiated By Timer
20:54 Operating Mode Changed to Defrost
21:00 Controller Alarms: 53 - Battery Pack Failure
21:29 Defrost Terminated Due to Normal Operation
21:38 Operating Mode Changed to Modulated Cool
21:38 Operating Mode Changed to Cool Reduced
22:00 Controller Alarms: 53 - Battery Pack Failure
22:03 Operating Mode Changed to Cool Max
23:00 Controller Alarms: 53 - Battery Pack Failure
_______________________________________________________

May 06, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -18.31   -8.52
02:00    -12.22   -3.17
03:00    -18.87   -8.91
08:00     -7.53    0.24
09:00    -15.25   -7.60
10:00    -19.30   -9.82
11:00    -20.68  -10.53
12:00    -13.45   -5.88
13:00    -19.27   -9.70
14:00    -20.20  -10.71
15:00    -19.82  -10.73
16:00    -14.58   -6.83
17:00    -19.89  -10.67
18:00    -20.10  -11.20
19:00    -14.13   -6.70
20:00    -18.35   -9.44
21:00    -19.74  -10.48
22:00    -20.41  -11.52

May 06, 2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
00:40 Defrost Initiated By Timer
00:40 Operating Mode Changed to Defrost
01:00 Controller Alarms: 53 - Battery Pack Failure
01:16 Defrost Terminated Due to Normal Operation
01:25 Operating Mode Changed to Cool Reduced
01:44 Operating Mode Changed to Cool Max
02:00 Controller Alarms: 53 - Battery Pack Failure
03:00 Controller Alarms: 53 - Battery Pack Failure
03:29 Power Down (Battery Not Present)
07:26 Power On (Battery Not Present)
07:27 Controller Alarms: 53 - Battery Pack Failure
07:27 Operating Mode Changed to Cool Reduced
07:33 Defrost Initiated By Keypad
07:33 Operating Mode Changed to Defrost
07:57 Defrost Terminated Due to Normal Operation
08:00 Controller Alarms: 53 - Battery Pack Failure
08:06 Operating Mode Changed to Cool Reduced
08:26 Operating Mode Changed to Cool Max
09:00 Controller Alarms: 53 - Battery Pack Failure
10:00 Controller Alarms: 53 - Battery Pack Failure
11:00 Controller Alarms: 53 - Battery Pack Failure
11:07 Defrost Initiated By Timer
11:34 Defrost Terminated Due to Normal Operation
11:42 Operating Mode Changed to High Speed Evaps
11:43 Operating Mode Changed to Cool Reduced
12:00 Controller Alarms: 53 - Battery Pack Failure
12:02 Operating Mode Changed to Cool Max
13:00 Controller Alarms: 53 - Battery Pack Failure
14:00 Controller Alarms: 53 - Battery Pack Failure
14:44 Defrost Initiated By Timer
14:44 Operating Mode Changed to Defrost
15:00 Controller Alarms: 53 - Battery Pack Failure
15:11 Defrost Terminated Due to Normal Operation
15:20 Operating Mode Changed to Cool Reduced
15:25 Operating Mode Changed to Cool Max
16:00 Controller Alarms: 53 - Battery Pack Failure
17:00 Controller Alarms: 53 - Battery Pack Failure
18:00 Controller Alarms: 53 - Battery Pack Failure
18:21 Defrost Initiated By Timer
18:47 Defrost Terminated Due to Normal Operation
18:56 Operating Mode Changed to Modulated Cool
18:56 Operating Mode Changed to Cool Reduced
19:00 Controller Alarms: 53 - Battery Pack Failure
19:19 Operating Mode Changed to Cool Max
20:00 Controller Alarms: 53 - Battery Pack Failure
21:00 Controller Alarms: 53 - Battery Pack Failure
21:58 Defrost Initiated By Timer
21:58 Operating Mode Changed to Defrost
22:00 Controller Alarms: 53 - Battery Pack Failure
22:25 Defrost Terminated Due to Normal Operation
22:33 Operating Mode Changed to High Speed Evaps
_______________________________________________________

May 06, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
23:00    -12.95   -5.66
24:00    -18.74  -10.03

May 06, 2016
Time  Event Data
22:33 Operating Mode Changed to Modulated Cool
22:34 Operating Mode Changed to Cool Reduced
23:00 Controller Alarms: 53 - Battery Pack Failure
23:00 Operating Mode Changed to Cool Max
_______________________________________________________

May 07, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -19.29  -10.51
02:00    -17.41   -8.29
03:00    -15.16   -8.51
04:00    -13.76   -5.43
05:00    -18.92  -10.20
06:00    -20.35  -11.16
07:00    -21.13  -12.13
08:00    -14.10   -6.49
09:00    -20.42  -11.37
10:00    -21.04  -11.92
11:00    -19.05   -9.98
12:00    -16.46   -8.97
13:00    -21.05  -12.10
15:00    -18.03   -9.30
16:00    -21.77  -12.35
17:00    -19.35   -9.37
18:00    -16.20   -8.67
19:00    -20.63  -11.39
20:00    -20.82  -11.71

May 07, 2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
01:00 Controller Alarms: 53 - Battery Pack Failure
01:35 Defrost Initiated By Timer
01:35 Operating Mode Changed to Defrost
02:00 Controller Alarms: 53 - Battery Pack Failure
02:01 Defrost Terminated Due to Normal Operation
02:09 Operating Mode Changed to Cool Reduced
02:31 Operating Mode Changed to Cool Max
03:00 Controller Alarms: 53 - Battery Pack Failure
03:22 Defrost Initiated By Keypad
03:47 Defrost Terminated Due to Normal Operation
03:55 Operating Mode Changed to Modulated Cool
03:55 Operating Mode Changed to Cool Reduced
04:00 Controller Alarms: 53 - Battery Pack Failure
04:15 Operating Mode Changed to Cool Max
05:00 Controller Alarms: 53 - Battery Pack Failure
06:00 Controller Alarms: 53 - Battery Pack Failure
06:58 Defrost Initiated By Timer
06:58 Operating Mode Changed to Defrost
07:00 Controller Alarms: 53 - Battery Pack Failure
07:25 Defrost Terminated Due to Normal Operation
07:33 Operating Mode Changed to Cool Reduced
07:52 Operating Mode Changed to Cool Max
08:00 Controller Alarms: 53 - Battery Pack Failure
09:00 Controller Alarms: 53 - Battery Pack Failure
10:00 Controller Alarms: 53 - Battery Pack Failure
10:36 Defrost Initiated By Timer
10:36 Operating Mode Changed to Defrost
11:00 Controller Alarms: 53 - Battery Pack Failure
11:03 Defrost Terminated Due to Normal Operation
11:11 Operating Mode Changed to Cool Reduced
11:30 Operating Mode Changed to Cool Max
12:00 Controller Alarms: 53 - Battery Pack Failure
13:00 Controller Alarms: 53 - Battery Pack Failure
13:06 Power Down (Battery Not Present)
14:33 Power On (Battery Not Present)
14:33 Controller Alarms: 53 - Battery Pack Failure
14:34 Operating Mode Changed to Cool Reduced
14:35 Operating Mode Changed to Cool Max
15:00 Controller Alarms: 53 - Battery Pack Failure
16:00 Controller Alarms: 53 - Battery Pack Failure
16:33 Defrost Initiated By Keypad
16:33 Operating Mode Changed to Defrost
17:00 Controller Alarms: 53 - Battery Pack Failure
17:02 Defrost Terminated Due to Normal Operation
17:11 Operating Mode Changed to Cool Reduced
17:12 Operating Mode Changed to Cool Max
18:00 Controller Alarms: 53 - Battery Pack Failure
19:00 Controller Alarms: 53 - Battery Pack Failure
20:00 Controller Alarms: 53 - Battery Pack Failure
20:13 Defrost Initiated By Timer
20:13 Operating Mode Changed to Defrost
20:42 Defrost Terminated Due to Normal Operation
_______________________________________________________

May 07, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
21:00    -13.84   -4.75
22:00    -19.30  -10.57
23:00    -18.97  -10.29
24:00    -14.03   -4.67

May 07, 2016
Time  Event Data
20:51 Operating Mode Changed to Cool Reduced
20:55 Operating Mode Changed to Cool Max
21:00 Controller Alarms: 53 - Battery Pack Failure
22:00 Controller Alarms: 53 - Battery Pack Failure
22:46 Defrost Initiated By Keypad
22:46 Operating Mode Changed to Defrost
23:00 Controller Alarms: 53 - Battery Pack Failure
23:13 Defrost Terminated Due to Normal Operation
23:21 Operating Mode Changed to Cool Reduced
23:23 Operating Mode Changed to Cool Max
_______________________________________________________

May 08, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -19.57  -10.76
02:00    -20.17  -11.32
03:00    -14.65   -5.42
04:00    -18.92  -10.45
05:00    -20.92  -11.67
06:00    -21.62  -12.20
07:00    -14.34   -5.31
08:00    -14.17   -5.11
09:00    -20.99  -11.74
10:00    -19.70  -10.21
11:00    -16.31   -7.00
12:00    -21.63  -12.24
13:00    -22.23  -12.81
14:00    -15.56   -6.30
15:00    -21.11  -12.01
16:00    -22.29  -12.94
17:00    -21.33  -12.42
18:00    -15.46   -5.86
19:00    -18.90   -8.59

May 08, 2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
01:00 Controller Alarms: 53 - Battery Pack Failure
02:00 Controller Alarms: 53 - Battery Pack Failure
02:23 Defrost Initiated By Timer
02:23 Operating Mode Changed to Defrost
02:51 Defrost Terminated Due to Normal Operation
02:59 Operating Mode Changed to High Speed Evaps
03:00 Controller Alarms: 53 - Battery Pack Failure
03:00 Operating Mode Changed to Cool Reduced
03:02 Operating Mode Changed to Cool Max
04:00 Controller Alarms: 53 - Battery Pack Failure
05:00 Controller Alarms: 53 - Battery Pack Failure
06:00 Controller Alarms: 53 - Battery Pack Failure
06:02 Defrost Initiated By Timer
06:31 Defrost Terminated Due to Normal Operation
06:40 Operating Mode Changed to Cool Reduced
06:41 Operating Mode Changed to Cool Max
07:00 Controller Alarms: 53 - Battery Pack Failure
07:02 Defrost Initiated By Keypad
07:26 Defrost Terminated Due to Normal Operation
07:35 Operating Mode Changed to Cool Reduced
07:36 Operating Mode Changed to Cool Max
08:00 Controller Alarms: 53 - Battery Pack Failure
09:00 Controller Alarms: 53 - Battery Pack Failure
09:38 Defrost Initiated By Keypad
09:38 Operating Mode Changed to Defrost
10:00 Controller Alarms: 53 - Battery Pack Failure
10:07 Defrost Terminated Due to Normal Operation
10:15 Operating Mode Changed to Cool Reduced
10:17 Operating Mode Changed to Cool Max
11:00 Controller Alarms: 53 - Battery Pack Failure
12:00 Controller Alarms: 53 - Battery Pack Failure
13:00 Controller Alarms: 53 - Battery Pack Failure
13:17 Defrost Initiated By Timer
13:47 Defrost Terminated Due to Normal Operation
13:56 Operating Mode Changed to Cool Reduced
13:57 Operating Mode Changed to Cool Max
14:00 Controller Alarms: 53 - Battery Pack Failure
15:00 Controller Alarms: 53 - Battery Pack Failure
16:00 Controller Alarms: 53 - Battery Pack Failure
16:45 Defrost Initiated By Keypad
16:45 Operating Mode Changed to Defrost
17:00 Controller Alarms: 53 - Battery Pack Failure
17:13 Defrost Terminated Due to Normal Operation
17:22 Operating Mode Changed to Cool Reduced
17:24 Operating Mode Changed to Cool Max
18:00 Controller Alarms: 53 - Battery Pack Failure
18:38 Defrost Initiated By Keypad
18:38 Operating Mode Changed to Defrost
19:00 Controller Alarms: 53 - Battery Pack Failure
19:03 Defrost Terminated Due to Normal Operation
_______________________________________________________

May 08, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
20:00    -15.96   -7.93
21:00    -20.61  -11.57
22:00    -20.97  -12.35
23:00    -14.24   -5.23
24:00    -19.47  -10.89

May 08, 2016
Time  Event Data
19:12 Operating Mode Changed to Cool Reduced
19:14 Operating Mode Changed to Cool Max
20:00 Controller Alarms: 53 - Battery Pack Failure
21:00 Controller Alarms: 53 - Battery Pack Failure
22:00 Controller Alarms: 53 - Battery Pack Failure
22:14 Defrost Initiated By Timer
22:43 Defrost Terminated Due to Normal Operation
22:52 Operating Mode Changed to Cool Reduced
22:56 Operating Mode Changed to Cool Max
23:00 Controller Alarms: 53 - Battery Pack Failure
_______________________________________________________

May 09, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -20.26  -11.49
02:00    -20.58  -12.14
03:00    -13.78   -4.75
07:00    -19.09  -10.13
08:00    -21.74  -12.27
09:00    -22.53  -13.63
10:00    -15.22   -6.40
11:00    -21.43  -12.08
12:00    -22.24  -12.84
13:00    -21.97  -12.95
14:00    -15.62   -6.00
15:00    -17.73  -10.43
16:00    -22.35  -12.93
17:00    -21.80  -12.87
18:00    -14.97   -5.34
19:00    -15.31   -5.80
20:00    -21.07  -11.97
21:00    -21.23  -12.55

May 09, 2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
01:00 Controller Alarms: 53 - Battery Pack Failure
01:53 Defrost Initiated By Timer
01:53 Operating Mode Changed to Defrost
02:00 Controller Alarms: 53 - Battery Pack Failure
02:21 Defrost Terminated Due to Normal Operation
02:30 Operating Mode Changed to Cool Reduced
02:49 Operating Mode Changed to Cool Max
03:00 Controller Alarms: 53 - Battery Pack Failure
03:45 Power Down (Battery Not Present)
06:04 Power On (Battery Not Present)
06:05 Controller Alarms: 53 - Battery Pack Failure
06:05 Operating Mode Changed to Cool Reduced
06:07 Operating Mode Changed to Cool Max
07:00 Controller Alarms: 53 - Battery Pack Failure
08:00 Controller Alarms: 53 - Battery Pack Failure
09:00 Controller Alarms: 53 - Battery Pack Failure
09:07 Defrost Initiated By Timer
09:38 Defrost Terminated Due to Normal Operation
09:46 Operating Mode Changed to Cool Reduced
09:48 Operating Mode Changed to Cool Max
10:00 Controller Alarms: 53 - Battery Pack Failure
11:00 Controller Alarms: 53 - Battery Pack Failure
12:00 Controller Alarms: 53 - Battery Pack Failure
12:48 Defrost Initiated By Timer
12:49 Operating Mode Changed to Defrost
13:00 Controller Alarms: 53 - Battery Pack Failure
13:18 Defrost Terminated Due to Normal Operation
13:27 Operating Mode Changed to Cool Reduced
13:29 Operating Mode Changed to Cool Max
14:00 Controller Alarms: 53 - Battery Pack Failure
14:24 Power Down (Battery Not Present)
14:50 Power On (Battery Not Present)
14:51 Operating Mode Changed to Cool Reduced
14:52 Operating Mode Changed to Cool Max
15:00 Controller Alarms: 53 - Battery Pack Failure
16:00 Controller Alarms: 53 - Battery Pack Failure
16:46 Defrost Initiated By Keypad
16:46 Operating Mode Changed to Defrost
17:00 Controller Alarms: 53 - Battery Pack Failure
17:16 Defrost Terminated Due to Normal Operation
17:26 Operating Mode Changed to Cool Max
17:47 Defrost Initiated By Keypad
17:47 Operating Mode Changed to Defrost
18:00 Controller Alarms: 53 - Battery Pack Failure
18:12 Defrost Terminated Due to Normal Operation
18:21 Operating Mode Changed to Cool Reduced
18:41 Operating Mode Changed to Cool Max
19:00 Controller Alarms: 53 - Battery Pack Failure
20:00 Controller Alarms: 53 - Battery Pack Failure
21:00 Controller Alarms: 53 - Battery Pack Failure
21:23 Defrost Initiated By Timer
21:23 Operating Mode Changed to Defrost
21:51 Defrost Terminated Due to Normal Operation
_______________________________________________________

May 09, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
22:00    -15.49   -6.33
23:00    -18.95  -10.89
24:00    -20.44  -11.81

May 09, 2016
Time  Event Data
21:59 Operating Mode Changed to High Speed Evaps
22:00 Controller Alarms: 53 - Battery Pack Failure
22:00 Operating Mode Changed to Cool Reduced
22:14 Operating Mode Changed to Cool Max
23:00 Controller Alarms: 53 - Battery Pack Failure
_______________________________________________________

May 10, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -20.78  -12.24
02:00    -13.80   -4.70
03:00    -20.49  -11.77
04:00    -21.47  -12.50
05:00    -20.39  -11.79
06:00    -15.93   -6.62
07:00    -21.75  -13.01
08:00    -22.31  -13.48
09:00    -16.37   -6.46
10:00    -20.81  -12.42
11:00    -15.59   -5.90
12:00    -21.81  -12.75
13:00    -22.59  -13.53

May 10, 2016
Time  Event Data
00:00 Controller Alarms: 53 - Battery Pack Failure
01:00 Controller Alarms: 53 - Battery Pack Failure
01:02 Defrost Initiated By Timer
01:30 Defrost Terminated Due to Normal Operation
01:39 Operating Mode Changed to Cool Reduced
01:41 Operating Mode Changed to Cool Max
02:00 Controller Alarms: 53 - Battery Pack Failure
03:00 Controller Alarms: 53 - Battery Pack Failure
04:00 Controller Alarms: 53 - Battery Pack Failure
04:41 Defrost Initiated By Timer
04:41 Operating Mode Changed to Defrost
05:00 Controller Alarms: 53 - Battery Pack Failure
05:10 Defrost Terminated Due to Normal Operation
05:19 Operating Mode Changed to Cool Reduced
05:20 Operating Mode Changed to Cool Max
06:00 Controller Alarms: 53 - Battery Pack Failure
07:00 Controller Alarms: 53 - Battery Pack Failure
08:00 Controller Alarms: 53 - Battery Pack Failure
08:21 Defrost Initiated By Timer
08:21 Operating Mode Changed to Defrost
08:51 Defrost Terminated Due to Normal Operation
08:59 Operating Mode Changed to High Speed Evaps
09:00 Controller Alarms: 53 - Battery Pack Failure
09:00 Operating Mode Changed to Cool Reduced
09:02 Operating Mode Changed to Cool Max
10:00 Controller Alarms: 53 - Battery Pack Failure
10:09 Defrost Initiated By Keypad
10:36 Defrost Terminated Due to Normal Operation
10:45 Operating Mode Changed to Cool Reduced
10:47 Operating Mode Changed to Cool Max
11:00 Controller Alarms: 53 - Battery Pack Failure
12:00 Controller Alarms: 53 - Battery Pack Failure
13:00 Controller Alarms: 53 - Battery Pack Failure
13:33 Power Down (Battery Not Present)
_______________________________________________________

May 11, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: IRCU200215-2, Serial : 04102615

Time     SupAir  RetAir
01:00    -11.80   -5.71
02:00    -16.86   -9.69
04:00    -13.20   -7.12
05:00    -17.97  -10.23
06:00    -19.87   -7.51
07:00    -14.65   -2.10
08:00    -12.54   -4.22
09:00    -19.20  -10.60
10:00    -21.46   -9.43
11:00    -15.09   -2.36
12:00    -16.17   -9.77
13:00    -19.73  -11.40
14:00    -21.58  -10.92
15:00    -12.92   -3.52
16:00    -19.06  -10.37
17:00    -20.35  -11.89
18:00    -20.94  -10.97
19:00     -9.07    0.43

May 11, 2016
Time  Event Data
00:19 Power On (Battery Not Present)
00:20 Controller Alarms: 53 - Battery Pack Failure
00:20 Operating Mode Changed to Cool Reduced
00:33 Operating Mode Changed to Cool Max
01:00 Controller Alarms: 53 - Battery Pack Failure
02:00 Controller Alarms: 53 - Battery Pack Failure
02:39 Power Down (Battery Not Present)
03:23 Power On (Battery Not Present)
03:23 Controller Alarms: 53 - Battery Pack Failure
03:24 Operating Mode Changed to Cool Reduced
03:29 Operating Mode Changed to Cool Max
04:00 Controller Alarms: 53 - Battery Pack Failure
05:00 Controller Alarms: 53 - Battery Pack Failure
06:00 Controller Alarms: 53 - Battery Pack Failure
06:26 Defrost Initiated By Timer
06:26 Operating Mode Changed to Defrost
07:00 Controller Alarms: 53 - Battery Pack Failure
07:08 Defrost Terminated Due to Normal Operation
07:17 Operating Mode Changed to Cool Reduced
07:19 Operating Mode Changed to Cool Max
08:00 Controller Alarms: 53 - Battery Pack Failure
09:00 Controller Alarms: 53 - Battery Pack Failure
10:00 Controller Alarms: 53 - Battery Pack Failure
10:19 Defrost Initiated By Timer
10:19 Operating Mode Changed to Defrost
10:56 Defrost Terminated Due to Normal Operation
11:00 Controller Alarms: 53 - Battery Pack Failure
11:05 Operating Mode Changed to Cool Reduced
11:07 Operating Mode Changed to Cool Max
12:00 Controller Alarms: 53 - Battery Pack Failure
13:00 Controller Alarms: 53 - Battery Pack Failure
14:00 Controller Alarms: 53 - Battery Pack Failure
14:06 Defrost Initiated By Timer
14:41 Defrost Terminated Due to Normal Operation
14:50 Operating Mode Changed to Cool Reduced
14:51 Operating Mode Changed to Cool Max
15:00 Controller Alarms: 53 - Battery Pack Failure
16:00 Controller Alarms: 53 - Battery Pack Failure
17:00 Controller Alarms: 53 - Battery Pack Failure
17:51 Defrost Initiated By Timer
17:51 Operating Mode Changed to Defrost
18:00 Controller Alarms: 53 - Battery Pack Failure
18:27 Defrost Terminated Due to Normal Operation
18:42 Operating Mode Changed to Cool Max
18:45 Operating Mode Changed to Cool Reduced
19:00 Controller Alarms: 53 - Battery Pack Failure
19:08 Operating Mode Changed to Cool Max
19:54 Container ID Changed to ircu2002152
_______________________________________________________

May 11, 2016
Setpoint: -25.00, O2: OFF, CO2: OFF, Container: ircu2002152, Serial : 04102615

2 Sensors Logged at 60 minute interval.
Sensor Format   Resolution
Supply Average  High
Return Average  High

No Sensor Data

Time  Event Data
19:55 Data Retrieval
_______________________________________________________